Physical Parameter Standards to Judge Retort Sterilization Completion

To judge whether retort sterilization is fully completed by physical parameters, three core indicators must reach and stay at the qualified standard at the same time: temperature, pressure and constant holding time.
 
  1. Sterilization Temperature
     
    The internal chamber temperature and product cold-point temperature must reach the required sterilization temperature and keep stable.
     
    Common standard: 121°C, 135°C or customized temperature according to food formula.
     
    Allowable fluctuation range: ±0.5°C ~ ±1°C, no obvious temperature drop during the holding stage.
     
  2. Matching Working Pressure
     
    Maintain the saturated steam pressure corresponding to the sterilization temperature.
     
    Stable pressure ensures balanced inside and outside of packaging, prevents bag expansion, cracking or tank deformation, and guarantees continuous heat transmission.
     
    No sudden pressure drop or overpressure alarm during the whole sterilization process.
     
  3. Effective Constant Temperature Holding Time
     
    Only the time after the temperature reaches the set sterilization standard can be counted as effective sterilization time.
     
    The cumulative holding time must fully meet the technological requirement.
     
    If temperature or pressure drops in the middle, the timing will be invalid, and supplementary holding time is required.
     
  4. Complete Data Recording
     
    Continuous temperature and pressure curve without interruption, blank point or abnormal fluctuation.
     
    Complete heating, constant temperature, cooling and pressure relief process in sequence.
     
  5. Qualified Cooling & Pressure Relief
     
    After sterilization holding finished, complete gradual cooling and pressure relief.
     
    Product core temperature drops to below 40°C, to avoid thermal over-cooking and secondary bacterial breeding.